C3 |
|
Test Code |
271 |
Unit |
mg/dL |
Station |
Chemistry |
Synonym Name/Abbreviation |
Complement C3 |
CPT Code |
86160 |
Performing Facility |
American Medical Labs, Herzliya |
Analyzer |
Roche cobas 6000 |
Test Method |
Immunoturbidimetric assay |
AML Preferred Tube |
Serum |
Storage Instructions |
Refrigerated. Stability: 4 days 15 to 25 oC 8 days 2 to 8 oC 8 days -15 to-25 oC |
Min. Volume |
1 mL |
Turn-Around-Time |
One day |
Intended Use |
Quantitation of C3 is used to detect individuals |
Limitations |
Detects both biologically active and inactive C3. Measuring range: 50-300 |
Patient Preparation |
No specific instructions |
Reasons for Rejection |
Excessive lipemia (>1500 mg/dL) significantly increases |
Adult Reference Ranges |
Male and Female: 90 – 180 |